Why a Parameter in the Verify Module is Connected but not Linking, not Visible, not Checking

When a parameter is not being checked in the Verify module, it is usually due to three common causes. This article explains each reason and how to troubleshoot it effectively

Contents

1. Typo or Mismatch in the Parameter Name

One of the most common issues is a mismatch between the parameter name in the model and the information requirement name in Plannerly. This mismatch may be very subtle - even a single whitespace can break the link. Capital letters do not matter, but every space does.

To verify an exact match:

  1. In the Verify Model view, select the element and open the Properties tab.
  2. Copy the parameter name directly from there.
  3. In Scope, click Requirements, then the search icon in the panel that opens. Your browser's search (Ctrl+F or Cmd+F) can miss rows here, because the list only loads the rows on screen.
  4. Paste the parameter name and search for a 100% match.

Note: Even with search, hidden whitespaces may still cause a mismatch. Perform this step in reverse as well: copy the information requirement name and paste it into Search properties in the Properties tab. Be sure to check for trailing spaces.


2. Parameter Required in a Specific Group / Pset / Category

Sometimes, the information requirement specifies that the parameter must be located within a particular group or property set (Pset). Plannerly will only accept the parameter if it is located in that specified group.

How to Check

  • Review the information requirement to see if a group, Pset, or category is defined in its Group column.
  • If a group is defined, the parameter must be inside that group.
  • If no group is specified, Plannerly accepts matching parameters from any group. In case of multiple parameters with the same name, the first match will be linked and investigated.

Action: Double-check both the model parameter location and the group setting inside the information requirement.


3. The Parameter Is on a Different Hierarchy Level

Plannerly maps each task to the lowest-level elements of the element tree by default. When it checks a mapped element, it looks for the parameter on that element first, then on its parents, nearest first. So in assembly and component structures (for example door - frame - handle - panel or sink - faucet relationships), a parameter stored on the parent assembly is still found. If the same parameter sits on both levels, the nearest one is used, even if it is empty.

Plannerly does not look down the tree. A parameter stored below the mapped element is not found.

Solution: Check the Mapped Level

The Map leaf elements setting decides which level of the model hierarchy is mapped to a task.

To change it:

  1. In the Verify module, find the relevant task on the Kanban board.
  2. Click the chain link icon on the task to open Map to Model Elements.
  3. Locate the Map leaf elements checkbox. When it is checked (the default), the lowest-level elements under whatever your rules select are mapped. When it is unchecked, the element your rules select is mapped itself.
Map leaf elements checkbox in the mapping window

Uncheck it to check an assembly as one element instead of each of its parts. Keep it checked if the parameter is stored on the parts.