Skip to main content

Create your company's own LOD scale in Plannerly

Set up a Geometry standard in Account settings: name each LOD level, say what the Geometry check looks for, set a pass mark and LOA bands, and use it on any project.

Contents

TL;DR - Open Account settings, then Company standards, and under Geometry standards select Add New. Name it, choose the built-in standard it's Based on, and rewrite any level's name, description or What the Geometry check looks for in your company's words. Set a Geometry check pass mark if you want one, then select Save. Any project can then pick it as its Project Standard.

Good to know - watch in your language: open the YouTube player settings (the gear icon), then under Subtitles/CC choose your language or use Auto-translate. If an auto-dubbed track is available, you can also switch the spoken voice under Audio track.

Who this is for

Account admins create, change and delete Geometry standards. Everyone else in the account can read them and, with permission to manage the project, pick one for a project.

Why it matters

Ask five people what LOD 300 means and you'll get six answers, usually in a long meeting. A Geometry standard writes down, once, what each level means for your company and what a checker should look for in the model. Every project that uses it then works to the same words, and the Geometry check judges models against them.


Create the standard

  1. Open the main menu (your profile picture) and choose Account settings.
  2. Open Company standards and find Geometry standards.
  3. Select Add New. A new standard opens, called something like Geometry standard 1, with the built-in wording already filled in.
  4. In Standard name, give it your company's name for it, for example Brightwater LOD 2027.
  5. In Based on, choose the built-in standard closest to how you work, such as a BIMForum or ISO 19650 scale. It gives each Geometry and Reliability combination its LOD label, such as LOD 300.
  6. Optional: in Geometry check pass mark, type the score a task needs to pass, as a whole number from 1 to 100. Leave it empty for the Plannerly default of 80%.

Say what each level means

  1. Open Geometry levels. For each level you can change its Name, its Description and What the Geometry check looks for.
  2. Do the same under Reliability levels.
  3. For as-built work, open As-built LOA bands and set each Band name and Tolerance.
  4. Select Save. Plannerly confirms Geometry standard saved.

Each field starts with the built-in wording, so you only change what your company does differently. A field you've changed is marked Changed, and Reset to built-in puts the original back. The Geometry and Reliability grid shows which combination carries which LOD label.

Tip: write What the Geometry check looks for as what you'd see in the model, not as a definition. For example: "Actual equipment shapes with their connection points and access zones, not boxes." The more concrete it is, the more useful the Geometry check's verdict.

Use it on a project

  1. Open the project and select Settings.
  2. Expand Standards and open Project Standard.
  3. Choose your standard. It's listed as an account Geometry standard, with the built-in standard it's based on.

The project's tasks now use your level names and meanings, and its Geometry check uses your standard's pass mark, unless the project sets its own under Settings, Verify, Geometry check. More about choosing a standard: Choose your project's LOD or LOIN standard.

Why this matters: a level of information need only works when everyone reads it the same way. One company standard, written in plain language and used on every project, takes LOD out of interpretation and makes it something you can check.

If it doesn't work

I can see the standards but can't change them

You'll see "Only account admins can change Geometry standards. You can see them here and pick them for a project." Ask an account admin, or see How to add another account admin in Plannerly.

My standard isn't in the Project Standard list

The project needs to belong to the same account as the standard, and choosing a standard needs permission to manage the project. Ask a project manager.

The pass mark won't save

It must be a whole number from 1 to 100, or empty. You'll see "Enter a whole number from 1 to 100." if it isn't.

What happens if I delete a standard?

Plannerly asks you to confirm. Projects that use it go back to the built-in standard it was based on, with the built-in wording.


Common questions

Can I create my own LOD scale in Plannerly?

Yes. A Geometry standard in Account settings lets you rename every level, describe it in your own words and say what a checker should look for, starting from a built-in scale.

What is the difference between geometry and reliability?

Geometry is how developed the shape is: Symbolic, Generic, Detailed or Fabrication in the built-in wording. Reliability is how far you can rely on it: Preliminary, Proposed, Coordinated or As-Built. Together they give the LOD label, such as LOD 300.

What is an LOA band?

Level of accuracy (LOA) describes how closely an as-built model must match what was built, as a measured tolerance. The Geometry check shows a task's LOA but doesn't score it, because tolerance can only be confirmed by measuring. More in LOD, LOIN and LOA explained.

Do I need the beta to use a Geometry standard?

No. Any account admin can create one and any project can use it. The Geometry check, which reads what each level looks for, is in beta - see Join the Plannerly beta testing community.

Can each project have its own pass mark?

Yes. A project's own pass mark, set in its Verify settings, wins over the standard's.



Take the free Certified Plannerly Administrator course - set up your company's standards, access and connections, with a certificate when you finish.